Heinen fire resistant doors

EI 30, EI 60, EI 120, EI 180, EI 240 (EN 1634-1)

Heinen fire-resistant doors have been designed to meet your needs in exceptional dimensions, while still meeting the requirements in terms of intensive use and mechanical resistance. For example, a Heinen double door, EI1-60, can easily compartmentalise an opening of 4.40 x 4.40 m!

normes-europeennes-feu-EN-1634
Icons-2

Dimensions et performances cumulables

Portes battantes scellées

Dimensions max. du vantail (L × H)
EI₁ 30
SIMPLE VANTAIL
DOUBLE VANTAIL
2175 x 4350
2175 x 4350
Sa, Sm
(S200)
JUSQU’À
CR5
CR2, CR3, CR4
JUSQU’À
54 dB
JUSQU’À
FB6
AK 47, FB4, FB5
EI₁ 60
SIMPLE VANTAIL
DOUBLE VANTAIL
2175 x 4350
2175 x 4350
Sa, Sm
(S200)
JUSQU’À
CR5
CR2, CR3, CR4
JUSQU’À
54 dB
JUSQU’À
FB6
AK 47, FB4, FB5
EI₁ 120
SIMPLE VANTAIL
DOUBLE VANTAIL
1600 x 3037
1600 x 3037
Sa, Sm
(S200)
JUSQU’À
CR3
CR2
SUR
DEMANDE
EI₁ 180
SIMPLE VANTAIL
1450 x 2652
Dimensions max. du vantail (L × H)
EI₂ 30
EI₂ 60
SIMPLE VANTAIL
DOUBLE VANTAIL
2175 x 4350
2175 x 4350
Sa, Sm
(S200)
JUSQU’À
CR5
CR2, CR3, CR4
JUSQU’À
54 dB
JUSQU’À
FB6
AK 47, FB4, FB5
EI₂ 90
EI₂ 120
SIMPLE VANTAIL
DOUBLE VANTAIL
1425 x 3035
1800 x 3035
Sa, Sm
(S200)
JUSQU’À
CR4
CR2, CR3
JUSQU’À
54 dB
JUSQU’À
FB4
AK 47
EI₂ 180
SIMPLE VANTAIL
DOUBLE VANTAIL
1280 x 2430
1280 x 2430
Sa, Sm
(S200)
JUSQU’À
CR3
CR2
SUR
DEMANDE
EI₂ 240
SIMPLE VANTAIL
1450 x 2652

* Certaines configurations peuvent nécessiter un avis de chantier

A pioneer in fire compartmentation

Heinen has always been a pioneer in fire-resistant compartmentalisation.

As early as 1973, the brand attracted attention by perfecting the world’s first metal fire-resistant door!

Since 2010, Heinen doors have been validated according to European standards by no fewer than 30 official fire tests. The pace of developments and the intensive activity in the R&D department even prompted the company to purchase its own furnace that meets European standards in order to carry out pre-tests.

CE marking

All Heinen external fire doors for pedestrians are CE marked according to the new European standards EN 16034 (fire doors) and EN 14351-1 (external pedestrian doors)

Laboratory test - HCM Fire resistance performance

The performance features

During a fire, it is crucial that a building’s structural elements maintain their integrity to ensure the safe evacuation of occupants. The structure must remain stable for the entire time required, while fire-resistant walls and doors serve to limit the spread of flames. Heinen provides solutions capable of withstanding up to 240 minutes, thus giving occupants valuable time to escape and allowing emergency services to intervene effectively.

Openings such as doors often represent the weak point in a fire compartmentation system. To address this challenge, Heinen has developed intumescent seals that expand when exposed to heat, thereby preventing the fire from spreading and, more critically, stopping the often lethal spread of smoke. Combined with certified smoke-tightness, these systems help maintain a clearer, more breathable atmosphere, which is vital both for occupants during evacuation and for firefighters during their operations.

Beyond these technical capabilities, Heinen’s range of fire doors is available in various fire-resistance ratings: 30, 60, 90, 120, 180, and 240 minutes for hinged doors. In a surface-mounted configuration, solutions offering 30 and 60 minutes of protection are available, while two-way doors provide 30 and 60 minutes of fire resistance. This broad selection meets the needs of diverse environments—be they residential, commercial, or industrial—while complying with all relevant safety and fire protection regulations.

Products available with fire resistant performance

  • Group-106-1_EN

    Single hinged door

    mortared or bolted frame

    Group-10
    Group-12
    Group-3
    Group-9
    Group
    Group-2
    Group-5
    Group-8
    Group-11
    Group-6
    Group-4
    Group-7
    Discover
  • Group-106-2_EN

    Double hinged door

    Mortared or bolted frame

    Group-10
    Group-12
    Group-3
    Group-9
    Group
    Group-2
    Group-5
    Group-8
    Group-11
    Group-6
    Group-4
    Group-7
    Discover
  • Group-108_EN

    Two-way door

    Mortared frame

    Group-9
    Group
    Icons-1
    Group-1
    Icons
    Discover
  • Group-109_EN

    Surface-mounted door

    Mortared frame

    Group-12
    Group-9
    Group
    Icons-1
    Group-1
    Group-6
    Icons
    Discover
  • Group-110_EN

    Hatch & trapdoor

    Mortared frame

    Discover
  • Group-110-2_EN

    Frame and glazed unit

    Mortared frame

    Discover
  • Group-110-1_EN

    Double door with no priority direction of opening

    Mortared frame

    Discover
  • Group-108-2_EN

    XXL hinged door

    Mortared frame

    Discover

Doors with cumulative performance

In addition to their long protection life and particularly wide range of sizes, Heinen doors can be combined with other performance features “à la carte”. Depending on your needs, one or more performances can be added to the basic METAL+ door.

Basic performance of the fire resistant doors

Possible combinations

Group-10

Acoustic

Group-12

Burglary resistance

Group-3

Blast-proof

Group-9

Anti-panic

Group-11

Bullet-proof protection

View
our data sheets and BIM objects

Specifications

Download the Heinen door specifications

You want to configure your doors combining bespoke performance features. You want to download BIM objects in various formats. Go to our Specifications and BIM section.

FTHE-0001-Metal-EI1-30-Hinged-door

FTHE 0001 – Metal+ EI1-30 – Hinged door

FTHE-0002-Metal-EI2-30-Hinged-door

FTHE 0002 – Metal+ EI2-30 – Hinged door

FTHE-0003-Metal-EI1-60-Hinged-door

FTHE 0003 – Metal+ EI1-60 – Hinged door

FTHE-0004-Metal-EI2-60-Hinged-door

FTHE 0004 – Metal+ EI2-60 – Hinged door

FTHE-0007-Metal-EI1-120-Hinged-door

FTHE 0007 – Metal+ EI1-120 – Hinged door

FTHE-0008-Metal-EI2-120-Hinged-door

FTHE 0008 – Metal+ EI2-120 – Hinged door

FTHE-0010-Metal-EI2-180-Hinged-door

FTHE 0010 – Metal+ EI2-180 – Hinged door

FTHE-0013-Metal-EI2-240-Single-and-double-Hinged-door

FTHE 0013 – Metal+ EI2-240 – Single and double Hinged door

FTHE-0101-Metal-EI1-30-Hinged-door

FTHE 0101 – Metal+ EI1-30 – Hinged door

FTHE-0102-Metal-EI2-30-Hinged-door

FTHE 0102 – Metal+ EI2-30 – Hinged door

FTHE-0104-Metal-EI2-60-Hinged-door

FTHE 0104 – Metal+ EI2-60 – Hinged door

FTHE-0108-Metal-EI2-120-Hinged-door

FTHE 0108 – Metal+ EI2-120 – Hinged door

FTHE-0201-Metal-EI1-30-Surface-mounted-Hinged-door

FTHE 0201 – Metal+ EI1-30 – Surface-mounted Hinged door

FTHE-0202-Metal-EI2-30-Surface-mounted-Hinged-door

FTHE 0202 – Metal+ EI2-30 – Surface-mounted Hinged door

FTHE-0203-Metal-EI1-60-Surface-mounted-Hinged-door

FTHE 0203 – Metal+ EI1-60 – Surface-mounted Hinged door

FTHE-0204-Metal-EI2-60-Surface-mounted-Hinged-door

FTHE 0204 – Metal+ EI2-60 – Surface-mounted Hinged door

FTHE-0301-Metal-EI1-30-Single-and-double-two-way-door-2

FTHE 0301 – Metal+ EI1-30 – Two-way door

FTHE-0302-Metal-EI2-30-Single-and-double-two-way-door-1

FTHE 0302 – Metal+ EI2-30 – Single and double two-way door

FTHE-0303-Metal-EI1-60-Single-and-double-two-way-door

FTHE 0303 – Metal+ EI1-60 – Two-way door

FTHE-0304-Metal-EI2-60-Single-and-double-two-way-door-1

FTHE 0304 – Metal+ EI2-60 – Two-way door